AmeriNOC.com maintains a custom private suite inside the carrier neutral AIS Data Center which is located in the San Diego Tech Center, inside the heart of the Sorrento Valley area of San Diego. The site offers a mix of cabinet, cage and custom space, as well as roof rights for microwave links and other antennae systems. The facility is fed from SDG&E with 4000 amps at 480 Volts.
The San Diego Tech Center is home to a number of data/telecom industry tenants and is rich with fiber, with every major carrier in the area represented. Fiber Providers include: AT&T, Cogent, Cox, Level 3, Telepacific, Time Warner, TW Telecom, Savvis, Sprint, Verizon and XO. Diverse fiber pathways accommodating Sonnet rings are provided from the listed carriers. The DC is a true carrier/optically neutral facility with large (2000 sq. ft) Meet Me Room and separate POP room for carriers and fiber providers. The AIS performance-routed blended network includes the following: AT&T, Global Crossing, Level 3, Savvis, Sprint, Verizon, XO & peering via Any2 Exchange & Cenic. This is the bandwidth product we use from AIS along with our direct connections to Level3 and Bandcon.
Many colocation companies these days claim to have state of the art facilities. When this facility was built, no expense was spared. 10 million dollars was spent to build 25,000 square feet of data center. An additional 5 million has been invested in network infrastructure and upgrades. It shows as well as it functions. Our facility is equal to or better than any facility ever built in San Diego. The AIS-Tech Center DC is a SSAE 16 compliant data center that features N+1 or better redundancy on all data center systems and security protocols required by leading businesses in the most stringent verticals.
Security
Camera with remote door release at all facility entrances - only authorized personnel are allowed to enter.
Biometric palm scanners at man trap entrance
Card access control at all interior doors
24/7/365 on-site security staff
24/7/365 intrusion detection monitoring
Digital surveillance cameras with six months storage on all main data center areas
All customer equipment is registered and can only be removed by authorized personnel
DC Power Systems
N+1 redundancy in all systems
1200 amps of 48 volt DC power
Dual DC plants with redundant "A" and "B" circuits provided to POP, Meet me Room and colocation areas
Valve-Regulated Lead-Acid (VRLA) batteries providing a minimum of 2 hours backup at full load
AC Power Systems
N+1 redundancy in all systems
4 Powerware 500KW Parallel redundant UPSs utilizing Hot Sync® technology
Valve-Regulated Lead-Acid (VRLA) batteries providing a minimum of 15 minutes backup at full load
Dual AC power available for POP, Meet me Room and colocation areas
2500 amps of 480 Volt AC power (Transformers step down to 208/120 Volts for customer use)
Generator
2 Megawatt Caterpillar Generator sized to run entire site at full load for a minimum of 48 hours without refueling, hot refuel capability.
Dual Automatic Transfer breakers and bypass/isolation switches provide N+1 redundancy for dual source power capability.
24 x 7 maintenance contract
Electrical connections for roll-up generator and load banks
Environment
Full data-grade HVAC system with N+1 redundancy
Triple redundant 200 ton Carrier chillers with Turbocor Upgrade
72 degree ambient air temperature (+/-2 degrees)
45% humidity (+/-5%)
580 tons of computer room air conditioning (CRAC) units, (2) 40 ton CRAC units, (8) 30 ton CRAC units, (2) 11 ton CRAC units and (10) 21 ton CRAC units
Fire Protection
Dry-pipe, pre-action double interlock fire suppression system
Both smoke and high temperature heat detectors
Zone specific discharge
45% humidity (+/-5%)
Early warning VESDA fire detection systems
Monitoring
DataTrax facility monitoring of Power, HVAC, Security, Fire, Leak Detection and Hydrogen Detection Systems
Network monitoring by NMS which monitors all network and customer connections
Systems is monitored on-site 24/7/365
Racks, Cabinets & Cages
24"W x 37"D x 84"H locking colocation cabinets with 19" mounting rails
24"W x 37"D x 105"H locking colocation cabinets with 19" mounting rails
30"W x 37"D x 84"H locking colocation cabinets with 23" mounting rails
Quarter, third and half cabinets with 19" mounting rails
Open 19" and 23" racks in POP and Meet Me Room
10' x 12' locking chain link cage space (120 square feet)
Custom cages built to customers specifications
Private space / larger square footage plans available